Module
Testing Plan
Trial Type
Movement Axis
X-axis right and Y-axis left 12", Y-axis back and forth 12", Z-axis up and down 4"
Pass/Fail - Multiple*
Dimensions
Overall dimension: 18"L x 18" x 12"H
Pass/Fail
DC Power Supply
Measure outputs max load connected. (12V/24V). Measure max current rate (15A).
Pass/Fail
Battery System
Test for short-circuit fault. Voltage cycle 3V ≤ 48V
Pass/Fail
System Circuit Breaker
Testing 15amp fused after power source for overload over 15amp
20 Trials Avg.
Estop Switch
Safety system connect with the main power supply
Pass/Fail
Limit Switch
Initial cutting spindle position x-axis to zero on left, y-axis to zero to forward position
Pass/Fail
Power Tool
Place lock mechanism (manual or electronic): milling, drilling, turning spindle
Pass/Fail
Microcontroller/Touchscreen
Verify successful compiling of Arduino programs. Display user input and relevant data.
Pass/Fail